NS8000 Series Network Sensors Catalog Page
Figure 1: NS8000 Series Network Sensor models ... (RH), carbon dioxide (CO2), motion, and local temperature setpoint adjustments. The sensor transmits this data to a controller on the Sensor/Actuator (SA) bus. Some NS Series Network Sensors models include an onboard passive infrared (PIR) occupancy sensor
Trend CO2/T/../S Space CO2, Humidity and Temperature ...
CO2 GND +24 Vac/dc 0 V}}} CO 2 CO 2 Temp. Temp. *Hum. *Hum. The 24 Vac/dc supply should be dedicated, isolated, and greater than 650 mA. *The humidity output is only available on CO2/T/H/DISP/S and CO2/T/H/S. backplate ‘click’ IQ Configuration Manual …
ZS Pro Sensor ZSPCAR
Temperature, CO2, Humidity, and VOC Sensor with Occupancy Status, Occupancy Override, and Setpoint Adjust LCD Display, Alarm Indicator, and Fan Speed Control Carrier’s line of intelligent ZS space sensors provide the function and flexibility you need to manage the conditions important to the comfort, productivity, and sustainability of your building.
Room Carbon Dioxide Transmitter HVAC Sensors and ...
The CD2RMC series uses a highly accurate and reliable Dual wavelength, Nondispersive Infrared (NDIR) sensor in an attractive, low profile enclosure for room applications to monitor CO2, levels. A linear analog signal output of 420 mA, 05 or 010 Vdc is provided for connection to a building automation system.
Introducing a New and Improved Set of Room Sensors from Veris!
15/7/2020· The new Veris Room Sensors come with a variety of configurations to help you seamlessly manage your building. Choose a single sensor to measure CO2, VOC, RH, or Temperature, or measure all four simultaneously. Veris is committed to providing air quality, temperature, and humidity sensors that offer the flexibility you want.
632571—16 C7232A,B Sensor and Controller
C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR APPLICATION The C7232 Sensor and Controller is a standalone carbon dioxide (CO2) sensor for use in determining ventilation necessity with HVAC controlle rs. The C7232 measures the CO2 concentration in the ventilated space or duct. The C7232 is used in ventilation and air conditioning systems
CDD5 CO2/RH/T Transmitter Installation Manual
The CO2/RH/T transmitter incorporates three sensors in one attractive wall mount enclosure for the most efficient environmental monitoring and control system. It uses Infrared Technology to monitor CO2 levels within a range of 0–2000 ppm or 20,000 ppm , a fieldproven RH sensor to monitor relative humidity from 0100 %RH and a
691710EFS 02 C7189U Remote Indoor Sensor
Sensor Resistance at Room Temperature. Room Temperature Ohms of °F °C Resistance 40 22537 42 21516 44 20546 46 19626 48 18754 50 17926 52 17136 54 16387 56 15675 58 14999 60 14356 62 13743 64 13161 66 12607 68 12081 70 11578 72 11100
ESCO2RM ESCO2RMPP CO2 Sensor Installation and ...
The sensor will monitor the carbon dioxide (CO2) and temperature (see note 1) within the room. If either reading reaches the low threshold values ( C1 T1) in fig. 5 then a signal will be sent to start running the fan at minimum speed. As the room CO2 and temperature rises, the fan speed will
Duco CO2 sensor RF User Manual
Free download of your Duco CO2 sensor RF User Manual. Still need help after reading the user manual? Post your question in our forums.
CO Sensor AAON
daisychained with the Digital Room Sensor (OE21700 or OE21701) or wired separately from the Orion Space Temperature Sensor (OE210, OE211, OE212, or OE213) for applications requiring both a room CO 2 sensor and room temperature sensor. See Figure 1 for dimensions. The OE25602 Duct Mounted CO 2 Sensor is comprised of the OE25601 CO 2
NS8000 Series Network Sensors Johnson Controls
With a bold new industrial design, the new NS8000 Series Network Sensors offer attractive form and practical function. Just one device handles sensing for temperature, humidity, CO2 and occupancy. These nextgeneration sensors cut wall clutter, reduce installation costs and help keep tenants happy. Features and Benefits.
DucoBox Energy 400 Heat Recovery Unit with Humidity Sensor ...
Description. DucoBox Energy 400 Heat Recovery Unit with Humidity Sensor and Heater DUCO4001zone. The DucoBox Energy 400 Heat Recovery unit is the quietest mechanical ventilation heat recovery unit in Europe! The DucoBox Energy 400 is intelligent, energy efficient and has a green A+ energy label. Key Features.
HUMIDITY/TEMPERATURE/C02/AIR QUALITY
Yes GSCO2RHT622LED Yes Yes SM36000 Room GSCO2RHT1001 Yes SM150000 Yes GSCO2RHT1001LED Yes SM160000 Room/Duct Carbon Dioxide Transmitters High reliability, low maintenance and BSF* compliant. Sontay’s new carbon dioxide sensor range uses a nondispersive infrared sensor for measuring CO2 concentrations in controlled spaces.
CO2 Gas Sensor User Manual – Vernier
Gas Sensor User Manual. The Vernier CO 2 Gas Sensor measures gaseous carbon dioxide levels by monitoring the amount of infrared radiation absorbed by carbon dioxide molecules. The sensor has two ranges: Low (0–10,000 ppm) and High (0–100,000 ppm). Students can use the CO 2 Gas Sensor to measure the change in carbon dioxide levels for a ...
OE21700 OE21701 Digital Room Sensors
The OE21704 EBUS Digital Room Space Humidity Sensor is used to sense Space Temperature Space Humidity. The EBUS Digital Room Sensor can be used with the VCCX2 or VCBX Controller. The EBUS Digital Room Sensor connects to the controller using EBUS cables of multiple lengths connected between the controller and the sensor. The
MRLDSCO2 Gas Detector Manual Emerson Electric
The MRLDSCO2 (P/N 8091020) is a fixed gas detector that detects the presence of CO. 2. refrigerant. The gas sensor can be used on a standalone basis or integrated into Controls or Building Management Systems (BMS). The MRLDSCO2 can be used: • In new buildings/areas that require continuous monitoring with high tech gas sensor transmitters.